Back to the Top
The following message was posted to: PharmPK
Hi,
I was wondering if anyone has experience collecting clinical samples
in the presences of THU, tetrahydrouridine, a cytidine-deaminase
inhibitor.
Are there vendors that supply blood collection tubes containing THU?
Are there vendors that make custom blood collection tubes?
Has anyone had to add THU to blood collection tubes prior to blood
collection at a clinical site?
If you have had experience with any of the above, please reply.
TK
Back to the Top
Hi Tara,
I am currently working on a trial that needs collection of blood
samples in THU treated vacutainers. The best way to avoid deamination
is to either collect blood in vacutainers preloaded with 0.05-0.1 ml
of tetrahydrouridine (10mg/ml) or add THU immediately after collection.
I am not sure of any vendors that supply THU coated tubes.
Refs:
1. J Clin Oncol., Vol 22, No 19 (October 1), 2004: pp. 3916-3921
2. J Clin Oncol. 2007 Jan 1;25(1):32-42
3. Annals of Oncology 15: 831-838, 2004
4. Anti-Cancer Drugs. 17(5):597-598, June 2006.
Hope this helps.
Ganesh
Back to the Top
Hi TK,
yes we've had experience with that. I do not know of any vendors for
THU-spiked tubes (and I don't think they exist). What we did:
The THU vial comes in 10 mg. add 1 mL of water (=10 mg/mL)
per 1 mL of blood to be collected you need 10 uL of the THU solution.
take a syring-needle as small as possible (I think they're called
insuline/tuberculine syringes?), anyway, the 0.5 mL type with the
needle attached.
fill the syringe with the amount of THU solution you need (50 uL for
a 5 mL blood tube)
puncture the seal of the vacutainer and add the solution (will be
sucked out of the syringe)
The seal will hold the remaining vacuum, you can even do this a
couple of days in advance.
Do take care to only fill the syringe for the volume needed for one
tube each time, the vacuum will suck out all the contents out of the
syringe.
Good luck, Jan
=Jan Hendrik Beumer
Pharm.D., Ph.D.
Assistant Professor Pharmaceutical Sciences
School of Pharmacy
The Hillman Cancer Center
Research Pavilion, Suite G.27d
5117 Centre Avenue
Pittsburgh, PA 15213-1863
Tel.lab.: +1-412-623-3238
Tel.off.: +1-412-623-3216
Fax.: +1-412-623-1212
Email: beumerjh.aaa.upmc.edu