Back to the Top
Dear All,
Can anyone suggest various ways of evaluating integrity of blood brain barrier in rodent models.
Warm Regards,
Ravi
Back to the Top
Evans blue
Back to the Top
Hi,
You could use radioactive sucrose or inulin as a marker for BBB integrity. You can then measure the
concentration of either using scintillation counting (after homogenizing the brain).
Alternatively, you could also use dyes such as fluorescein or texas-red which can be measured
through fluorescence (after sectioning the brain).
Best,
Rajneet
--
Rajneet Oberoi, PhD Candidate
Department of Pharmaceutics
University of Minnesota
Minneapolis, MN 55455